Why does my AC only blow out defrost?

Why does my AC only blow out defrost?

Symptoms/Behavior: AC only blows out defrost and floor – unable to get air to come out middle front vents. Mode selector has power and the icon on the dash changes when changing mode selection. AC works and blows cold. Temperature controls work.

How to get the AC mode selector out of defrost?

You will need to take a few trim panels off to get to the mode actuator. Remove upper dash panel above shelf (the one with the passenger side vent) – Pops out. Start on right hand side. Remove the five screws in the shelf area (three on top. two on bottom) and remove shelf. Remove kick panel under the glove box. Pops out.

What causes the defroster on a car to stop working?

A problem in your defrosting system can usually be traced to one of the following: 1 The cooling system 2 The heater core 3 The heater valves or blend air doors 4 The air conditioning system 5 The blower fan

How to remove AC mode selector / actuator in 2011?

Start on right hand side. Remove the five screws in the shelf area (three on top. two on bottom) and remove shelf. Remove kick panel under the glove box. Pops out. Pull down the rear edge and then pull away. Be gentle. Remove glove box by removing the two 8mm bolts at the bottom.

Symptoms/Behavior: AC only blows out defrost and floor – unable to get air to come out middle front vents. Mode selector has power and the icon on the dash changes when changing mode selection. AC works and blows cold. Temperature controls work.

What to do when air blows out of defroster vents?

Assuming that your actuator has failed in the most common position, blowing out of the defroster vents only, you should not have to do anything other than installing the actuator motor. No indexing of the door shafts to the cam/cog or recalibration of the actuator motors.

You will need to take a few trim panels off to get to the mode actuator. Remove upper dash panel above shelf (the one with the passenger side vent) – Pops out. Start on right hand side. Remove the five screws in the shelf area (three on top. two on bottom) and remove shelf. Remove kick panel under the glove box. Pops out.

Why are the vents on my GMC Sierra stuck?

The most common symptom of course is lack of control over the vent output position and normally it will be stuck in the defroster only position. If it is not currently stuck in the defroster position but you are changing the actuator anyways. make sure that you set the vent position to defrost before starting this procedure. You will see why later.

Assuming that your actuator has failed in the most common position, blowing out of the defroster vents only, you should not have to do anything other than installing the actuator motor. No indexing of the door shafts to the cam/cog or recalibration of the actuator motors.

What to do if your Honda Accord air vent is stuck?

Running a self-diagnosis can help identify the problem. To diagnose the problem, press the MODE (VENT/FLOOR) button several times. The LED should flash on and off as you press the button. Turn the ignition and the fan switch to the “OFF” position. Set the temperature control dial on Max Cool. Push the mode control button and select Vent.

What causes air vents to stay in defrost position?

If you have an older car then the defroster system is controlled by using vacuum supplied by the engine. Lift the hood and inspect the vacuum hose or tube that leads from the intake manifold to the passenger’s side firewall. The image below shows a typical line break which causes the vents to stay in the defrost position.

How does the climate system control the defroster?

The climate system is responsible for controlling the position of the defroster actuator which is connected to the air position door in the heater plenum. This actuator controls defrost, middle and lower air vents. When it fails it can do so in the defrost position and must be replaced.

Where does the vacuum line from the defroster go?

Vacuum lines travel from the vacuum control switch on the dash to vacuum servos under the dash. These servos move the air doors which turn on and off the defroster. If you can hear a hissing sound when the car is running from under the dash then vacuum is escaping.

How does the air vent work on a defroster?

The vent control system for the defroster in integrated into the operation of all temperature controls and uses forced air provided by the blower motor. On newer cars the vent direction and temperature controls are operated by a series of 3 or 4 electrical actuator motors which are adjusted by the climate control module.

Why do you need a defroster on an air conditioner?

You need a defroster to see where you are going. The defroster is part of the heater and air conditioner system which is housed inside of the heater plenum. The vent control system for the defroster in integrated into the operation of all temperature controls and uses forced air provided by the blower motor.

The climate system is responsible for controlling the position of the defroster actuator which is connected to the air position door in the heater plenum. This actuator controls defrost, middle and lower air vents. When it fails it can do so in the defrost position and must be replaced.

Can a climate control fan only blow defrost?

SilveradoSierra.com • Fan Only Blows Defrost, Won’t Change To Floor Or Vent. : Climate Control Fan Only Blows Defrost, Won’t Change To Floor Or Vent.

Is the Astro fan only blows defrost?

Re: Fan Only Blows Defrost, Won’t Change To Floor Or Vent. Yea the problem with them astro’s is the way the damn motor is crammed into the dog house with the heat it destroys the hard plastic vacume line . I have had 5 of them and every one had this problem until you change them out with rubber lines .

Why does AC stop blowing out the defrost vents?

After installing a new blower fan motor the ac would only come out the defrost vents. The factory vacuum check valve is very hard to get to. So i bypassed it. Now it is working like it should and ac comes out the dash vents. I do not have a vacuum reservoir installed i will have to see if i will need to add it later.

SilveradoSierra.com • Fan Only Blows Defrost, Won’t Change To Floor Or Vent. : Climate Control Fan Only Blows Defrost, Won’t Change To Floor Or Vent.

Why is my HVAC vent selector not working?

I have an ’02 TJ X and am having trouble with my HVAC vent selector. It will not switch into upper vent mode, only have the option to have it all on my feet, or feet and windshield. I searched but didnt find any real solutions. Help?

Re: Fan Only Blows Defrost, Won’t Change To Floor Or Vent. Yea the problem with them astro’s is the way the damn motor is crammed into the dog house with the heat it destroys the hard plastic vacume line . I have had 5 of them and every one had this problem until you change them out with rubber lines .