What is RW90 XLPE cable?
Voltage rating for RW90 cable is 600V. Conductors: Stranded soft drawn bare copper, with Class B stranding per ASTM. Insulation: Abrasion, heat and moisture resistant -40°C cross-linked polyethylene insulation (XLPE). Standards: RW90 meets or exceeds the following standards.
What is RWU90 cable?
Aluminum RWU90 is a cross linked polyethylene insulated single conductor The insulation is thicker than that of the RW90 making it suitable for direct earth burial. The available size range is from #8 AWG to 750 kcmil. Applications include service entrance below ground. RWU90 can only be specified as 1000 Volts.
Is RW90 sunlight resistant?
Applications and Features: Single copper conductor with low temperature, moisture resisting XLPE (cross linked polyethylene) insulation. Standard sizes 1/0 AWG and larger utilize SIMpull ® technology, are Sunlight Resistant in all colors and packaging.
Can RW90 be used underground?
With a rating of 600 volts, NUAL Brand RW90 can be installed in enclosed raceways in both wet and dry locations and are designed for use as service, feeder or branch circuits. Standard RW90 may be pulled into underground ducts, but is not approved for direct burial in earth.
What does RW90 cable stand for?
Moisture resistant 60°C. RW90: Canadian Standards Association (CSA) designation for a wire or cable with rubber or rubber like insulation suitable for use in wet or dry locations at a maximum temperature of 90°C.
Is RW90 outdoor rated?
Single copper conductor with low temperature moisture resisting Exelene* cross-linked polyethylene insulation. Standard Black #6 and larger is sunlight resistant and marked “Outdoor”; coloured insulation is NOT. Approved for use with ceiling fixtures.
What is RW 90 cable?
Single copper conductor, stranded and insulated with moisture, heat, and flame resistant, chemically crosslinked polyethylene.
Can you run RW90 in conduit?
CSA listed RW90 type stranded copper wire. This wire is rated for use in dry or wet locations, raceways, or conduit. It can be used outside exposed to the weather as well, though the insulation is not 100% UV-proof and installation in conduit is recommended.
How deep should electrical wire be buried in Ontario?
The Code requires non metallic sheathed cable (NMWU) to be buried at least 600 mm (24″) below non-vehicular areas and 900 mm (36″) below vehicular areas.
What is tw75 wire?
Single copper conductor, stranded and insulated with moisture and flame retardant, sunlight resistant PVC. Available with tinned conductors. Available in colors.
Does RW90 need to be in conduit?
What is RW90 cable used for?
Application For open wiring and raceways (except cable troughs and ventilated flexible cableway) in dry or wet locations. For exposed wiring where exposed to weather with sunlight resistant insulation. Approved for use with ceiling fixtures.
What kind of wire is a rw90 wire?
RW90 Building Wire, 12 AWG, 600V, Stranded Soft Drawn Plain Copper, XLPE, Black, CSA RW90 Building Wire, 250 MCM, 600V, Stranded Soft Drawn Plain Copper, XLPE, Black, CSA
When to use cme-rw90 / rw75 XLPE cable?
These cables are used in general purpose wiring in circuits not exceeding 2000 volts. May be used in wet or dry locations, installed in raceway, duct and aerial installations. For exposed wiring in wet locations, or exposed to weather.
What kind of wire is used in paralleled cable reels?
RW90 Building Wire, 250 MCM, 600V, Stranded Soft Drawn Plain Copper, XLPE, Black, CSA RW90 Building Wire, 750 MCM, 600V, Stranded Soft Drawn Plain Copper, XLPE, Black, CSA Enhance productivity and lower total installed costs with paralleled cable reels.