What is code 35 on a Thermo King unit?
Code 35 is for the microprocessor on the unit. There are software updates to help repair the units. You will have to test the board to make certain there are no problems with the unit.
What is code 10 on a Thermo King?
Thermo King Alarm Code 10: High Discharge Pressure.
What is code 17 on a Thermo King?
Code 17 means Engine Failed to Crank when start is requested by the Microprocessor. Check Starter (unfortunately lately new thermoking starters often fail for some reason). Fuel pull in Solenoid failed or its circuit.
How do I reset my thermoguard?
Press and hold TK and enter buttons at same time, for 5-7 seconds. With switch on and in continuous run mode, using up and down arrows, scroll to code and press enter, this will clear the code, If not I’ll have to walk you thru guarded access.
How do I fix code 10 on a Thermo King?
Thermo King Alarm Code 10: High Discharge Pressure
- Check for broken fan belts. This is the easiest item on the list.
- Check for a defective 12-volt battery. This is more common than you would expect.
- Check for a defective high-pressure cutout (HPCO) switch.
- Check the wiring harness on the 8D circuit.
What is code 18 on a Thermo King?
18 HIGH ENGINE COOLANT TEMPERATURE. 19 LOW ENGINE OIL PRESSURE. 20 ENGINE ( VAPOR MOTOR CR) FAILED TO START. 21 COOLING CYCLE CHECK.
How do I fix code 17 on a Thermo King?
What’s the most effective diagnostic procedure that should be followed for Alarm code 17?
- Check the battery for proper voltage, load test the battery to make sure that the battery internally is able to hold that charge.
- Check the fuse/relay interface circuit board for Fuse that controls the fuel shut off solenoid.
What are the fault codes for the Thermo King?
Thermo King Alarm Codes & Fault Codes. Thermo King Straight Truck Units – Most Popular. # 1 MD 200. # 2 TS 300. # 3 TS 500. # 4 RD II- SR. Thermo King Trailer Units – Most Popular. # 1 SB-III SR.
When to report Thermo King trailer unit alarm code?
Report this alarm at the end of the day. 09* High Evaporator Temperature If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day. 10* High Discharge Pressure (or Temperature) If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
When to report high discharge pressure on Thermo King truck?
09* High Evaporator Temperature If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day. 10* High Discharge Pressure (or Temperature) If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
What makes a Thermo Scientific TSX a high performance refrigerator?
Thermo Scientific TSX series refrigerators are high performance units designed with features that support sample protection and sustainability for storing media, reagents, chemotherapy and pharmaceutical compounds, and other medical- and laboratory-grade products requiring a storage environment of 3° to 7°C.