Depending on the system resonance point and the amount of capacitance, switching a utility power factor capacitor can create overvoltage condition on the customers low voltage bus. The voltage rise will be usually larger than a pure utility power factor capacitor switching.

Why does my Generator have a low voltage reading?

A bad capacity will result in a low voltage reading from the generator as the power being generated will be from the residual magnetism of the rotor (usually about 2-5V). To test a capacitor, a multi-meter that can test capacitance is required.

How does overvoltage protection work on a low HP drive?

Drive (VFD) overvoltage protection for common low HP drives is based on the measured voltage on the DC bus of the unit and not the input AC voltage. It is important to realize this fact to aid in troubleshooting. Any and all events that could cause a jump in DC bus voltage could lead to a dc link overvoltage fault event.

When is low voltage power factor correction capacitors switch?

When there is customer low voltage power factor correction capacitors at customer bus in addition to utility capacitors at utility bus, high transient overvoltage condition can develop when the capacitors at utility are switched.

How long does it take to find fault in a low voltage network?

In low voltage networks, which usually have no redundant power supply, the time intervals until a customer can be reconnected to the power supply greatly depend on the speed in locating the fault. Longer waiting periods due to a more remote fault location system are very problematic.

Is it possible to anticipate a LV cable fault?

In many cases, the joint position can also be very clearly delineated based on the known positions of the private connections. Since 80–90% of cable faults occur in joints, an anticipatory localisation of the fault is possible. Many LV cable faults change from transient to permanent (‘flickering lights’ are possible signs of a transient fault).

What causes intermittent fault in a street lighting network?

Intermittent fault location. Intermittent faults are very difficult to locate. Due to numerous joints and connections, these faults frequently occur in low voltage and street lighting networks. Corrosion in lamp masts and poor connections in joints lead to these faults.

What do the yellow and red warning lights mean?

The yellow warning lights mean that an action should be taken in the near future, and red lights inform you that action needs to be taken immediately. So, without further ado, Prestige Imports is pleased to present … Central Indicator Light – Check the message in the instrument cluster for additional information.