How do I reset my Worcester 28i junior boiler?
The appliance can be reset by pressing the fault indicator button and holding in for 5 seconds when the appliance has cooled. If this condition continues to occur, then call a service engineer.
Why is my Worcester boiler not coming on?
There are a variety of reasons why your boiler may not be working; common examples include the boiler pressure being too low or too high, a power cut, gas supply issues, a faulty pilot light, a frozen condensate pipe, faulty internal components or a more complex issue.
Why is the red light flashing on my Worcester boiler?
What Does A Worcester Boiler Flashing Red Light Mean? The boiler has no gas supply. The gas pressure has dropped too low. The flue is blocked.
What does the reset button do on a Worcester boiler?
Worcester Greenstar Ri Boiler Reset When the boiler resets the mains indicator will no longer be flashing and the boiler will function normally, dependant on the programmer and room thermostat settings. A reset fault condition will exist If the electrical power to the boiler has been interrupted.
How do I reset my Worcestershire boiler?
To reset the boiler turn the Central heating temperature knob anticlockwise to the “RESET” position and hold for approximately five seconds and then turn the knob back to the original temperature setting.
What should the pressure be on a Worcester boiler?
To work efficiently the Worcester combi boiler needs to operate on a standard pressure, between 1/ 2 bar, 1.5 bar is also a good pressure level. So, the pressure of the combi boiler needs to be topped up with cold water through the mains at some point in their lifetime.
Why does my boiler go into lockout?
What Does Lockout Mean on a Boiler? A boiler lockout is a shut-down procedure that initiates when a boiler is not working within certain tolerances. Boilers can lock out due to low/high water pressure, lack of, or no fuel supply (gas, LPG or oil), a blockage in the system, or the lack of power to electronic components.
Why does my Worcester Junior 28I combi boiler not fire?
Worcester Junior 28i Combi Boiler Fault. This combination boiler would not fire for domestic hot water after work to mains cold water supply pipework in street. During repair to the street cold water main, grit entered the domestic water main.
What should the water pressure be on a Worcester Boiler?
Low boiler pressure When the system is cool, the pressure gauge on a Worcester boiler should be between 1 – 1.5 (in the green section). Worcester boiler water pressure issues are common, especially for those that have been in use for some time.
What should I do if my Worcester Bosch boiler has a fault?
The Worcester Bosch fault finding table below will help you diagnose your boiler’s fault and help you take the next decision in fixing the issue. You may want to then buy a replacement part of get a service engineer in to fix the issue. Pump has run dry. Check system pressure, add water and bleed system as necessary. Hot water NTC Sensor defective.
Why does my Worcester Boiler keep cutting out?
There can be a number of reasons why your Worcester boiler keeps cutting out. It may be because of a faulty component, a drop in water pressure, or due to overheating. This lockout is designed to protect the overall system.