What kind of motor does a variable speed blower use?

What kind of motor does a variable speed blower use?

Variable speed blower motors don’t use a blower motor resistor. Instead they use a blower motor speed control or a power transistor. Variable speed motors are most often used in vehicles with automatic climate control.

What causes a blower motor to stop working?

In a situation where the motor doesn’t work on any speed, the most likely causes are: a blown power supply fuse, a bad motor ground connection, bad motor speed control module or a failed motor. On all systems, a failed blower motor is least likely. Blower motors generally don’t fail out of the clear blue.

Where does the power go in a blower motor?

For each higher speed, power flows through one less resistor. Some car makers run blower motor power through the fan speed switch first, then through the blower motor resistor and then to the blower motor and ground. Other car makers reverse that and run power to the blower motor first and terminate ground at the blower fan speed switch.

How are the resistors arranged in a blower motor?

Heating systems with just 3 or 4 speeds use a motor resistor along with the speed switch to regulate the motor speed. The resistors are arranged in series to reduce the voltage in steps, depending on where in the series you apply power. Blower resistors can burn out. When that happens, you lose that speed.

What can I do about intermittent blower motor?

Try cleaning it by cycling the control from minimum to maximum rapidly a dozen times or so with the truck off. If that does not work you could take the HVAC controller out and try to get some spray electrical contact cleaner inside the rheostat and again swiping it a number of times.

What to do if your blower is not working?

If that does not work you could take the HVAC controller out and try to get some spray electrical contact cleaner inside the rheostat and again swiping it a number of times.

Is the fan speed set or intermittent on a Silverado Sierra?

Just the blower is intermittent, not the compressor. Fan speed does not have set speeds, it’s more like a rheostat. It has the rotary control.

Is the fan speed control a variable speed?

Is your fan speed control a variable speed or does it have individual set speeds that can be selected for example, Off, 1, 2, 3, and so on? Just the blower is intermittent, not the compressor. Fan speed does not have set speeds, it’s more like a rheostat. It has the rotary control.

What causes a fuse to blow on a blower motor?

If the blower motor relay develops any sort of problem that hinders its ability to properly limit and distribute power, it may cause the blower motor fuse to blow. Any sort of electrical spikes or excessive current from a bad relay will blow the fuse and cut power in order to protect the system.

Why does my blower not work at high speeds?

Blower works on slow speeds, but not on high speed. Check for bad fuse or bad high speed relay. Swap the high speed relay with another relay with the same part number. Also, check the fuse for the control side of the high speed relay. Make sure the ground side of the high speed relay is working. Blower works on some speeds but not others

How to troubleshoot your furnace blower motor fan?

A third quick and simple troubleshooting step for your furnace blower motor is to make sure the filters and vents are clean and free of dust and debris. To do this, go to each of your home vents and ensure they are open and clear. Next check the cold air return filter for dirt or dust build up.

Blower works on slow speeds, but not on high speed. Check for bad fuse or bad high speed relay. Swap the high speed relay with another relay with the same part number. Also, check the fuse for the control side of the high speed relay. Make sure the ground side of the high speed relay is working. Blower works on some speeds but not others

Variable speed blower motors don’t use a blower motor resistor. Instead they use a blower motor speed control or a power transistor. Variable speed motors are most often used in vehicles with automatic climate control.

What are the symptoms of a bad heater motor resistor?

Symptoms of a Bad or Failing Heater Blower Motor Resistor. 1 1. Blower motor stuck on one speed. A common symptom of a faulty blower motor resistor is a blower motor that is stuck on one setting. The blower 2 2. Blower motor does not work on certain settings. 3 3. No air from the vehicle’s vents.

What should I do if my blower motor is not working?

If it’s good, refer to a wiring diagram for your vehicle and conduct these tests: Disconnect the electrical connector at the blower motor and jumper power and ground to the motor, bypassing all the speeds controls.

If it’s good, refer to a wiring diagram for your vehicle and conduct these tests: Disconnect the electrical connector at the blower motor and jumper power and ground to the motor, bypassing all the speeds controls.

Are there any problems with my Pathfinder 4 door?

Another rust problem is on the 4-door models, between the rear wheel opening and the bottom rear corner of the back door opening. One solution is to have anti-rust oil compound sprayed inside the back ends of the rocker panels. Another common area prone to rust is directly under the driver’s floor near the gas pedal where the exhaust pipes join.