How do I reset my Mircom FX 2000?
To reset the panel to normal, press the System Reset button.
What is the maximum number of loops on a FX 2000 large board?
The SGM-1004A occupies one module slot in the FX-2000 main or expander chassis. The ALC-H16 Hardwire Loop Controller Module allows the FX-2000 to support an additional sixteen (16) conventional hardwire adder modules.
Do I need to reset my fire alarm after it goes off?
If your smoke alarm won’t stop going off, reset the alarm after first checking that there is no actual fire in your home. If it is only a case of cooking smoke or steam setting off the alarm, most smoke alarms will stop beeping once you open windows and doors to air out the room.
How do you stop a fire alarm from beeping?
Resetting the Alarm
- Turn off the power to the smoke alarm at the circuit breaker.
- Remove the smoke alarm from the mounting bracket and disconnect the power.
- Remove the battery.
- Press and hold the test button for at least 15 seconds.
- Reconnect the power and reinstall the battery.
Where is the ground fault on a fire alarm panel?
To locate a ground fault, look for continuity to ground on each circuit. This new analog ohmmeter will show infinite ohms when the conductor is not exposed to an earth ground. If the insulation is compromised and/or the copper is directly connected to ground the ohmmeter will indicate 0 ohms.
Where is the earth fault on a fire alarm system?
To find a ground fault, the first thing you should do is *remove all wires from the fire alarm control panel. If the ground trouble goes away, then you’ve ruled out the possibility that it is not an internal ground within the control panel.
What causes fire alarm to go off?
The most likely reason smoke detectors go off unexpectedly is that people aren’t changing the batteries in them often enough. But most smoke detectors are instead designed to go off when their electrical current goes down. That’s because smoke in the air will reduce the current.
What are the features of an fx-2000 fire alarm?
Equipped with a large 4 x 20 Back-lit Alphanumeric LCD display, the FX-2000 utilizes a simple Menu system complete with a directional keypad, common control switches and LEDs, Alarm Queue switches and LEDs and two configurable input switches. Features
How many analog sensors are in the fx-2000?
The FX-2000 base panel consists of one intelligent analog loop controller capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A (Style 6 or 7) or Class B (Style 4). The system can be expanded by adding additional Analog Loop Controller Modules.
What is the base system of the fx-2000?
The base system consists of one analog loop and four indicating circuits. In addition the base system supports conventional hard wired modules. With its flexible modular design, the FX-2000 Series can be configured to meet challenging requirements without compromising its easy installation and operation.
Which is the remote display on the fx-2000?
The RAX-LCD Remote LCD Shared Display provides the same features as the main display on the FX-2000. In addition the RAX-LCD also acts as a driver module that allows for the RAX-1048TZDS, IPS-2424DS, FDX-008 and AGD-048 to be connected to it.