Why is my universal fuel sender not working?
If you cannot make your gauge read anything but full then depending on your ohm range you may have one of the following problems: If you have a 0-30, 0-90 or 10-180 Ohm sender then the sender may not have a proper ground or there is a break in the sender lead wire.
Where is the Black probe on universal fuel sender?
With the multimeter set to the Ω setting put the red probe on the post that is the gauge lead and put the black probe on the ground post or on the body of the fuel sender. Record your readings with the fuel sender in the empty position and in the full position.
Can a 73-10 ohm fuel sender read backwards?
For example a 73-10 ohm fuel sender would read backwards on a 0-90 ohm fuel gauge. If you find you have the correct ohm range fuel sender make sure that the float arm is installed on the correct side.
What is resistance to ground on universal fuel sender?
When the fuel sender is in the full position the rheostat is creating 90 ohms of resistance to ground. Because the gauge is reading a resistance to ground having proper grounding of the sending unit is essential to get an accurate reading on your fuel gauge. How do I test my fuel sender?
If you cannot make your gauge read anything but full then depending on your ohm range you may have one of the following problems: If you have a 0-30, 0-90 or 10-180 Ohm sender then the sender may not have a proper ground or there is a break in the sender lead wire.
Do you need to replace sender and fuel gauge?
In most cases, the sender and the fuel gauge need to be matched to the resistance in the sender’s rheostat, so to be completely sure you are getting accurate readings, replace both the sender and the gauge. Several companies provide pre-packaged “ready-to-go” installation kits. Most sensors have a mechanical floating arm and a rheostat.
With the multimeter set to the Ω setting put the red probe on the post that is the gauge lead and put the black probe on the ground post or on the body of the fuel sender. Record your readings with the fuel sender in the empty position and in the full position.
For example a 73-10 ohm fuel sender would read backwards on a 0-90 ohm fuel gauge. If you find you have the correct ohm range fuel sender make sure that the float arm is installed on the correct side.