What is the R-value of Owens Corning insulation?

What is the R-value of Owens Corning insulation?

11 and 19
Owens Corning EcoTouch PINK Fiberglas Insulation with PureFiber Technology is a preformed, flexible blanket insulation. It is produced in R-values of 11 and 19, with thicknesses of 3.5 inches and 6.25 inches.

What is the R-value of 3 1/2 inch fiberglass insulation?

For example, standard low-density batts, at their nominal rated thickness — R-11 at 3 1/2 inches, or R-19 at 6 inches — have an R-value of about 3.1 per inch. If you compress a 6-inch R-19 batt into a 3 1/2-inch cavity, you get about R-14, or 4.0 per inch.

What is the R-value of 1 inch of fiberglass insulation?

Comparative Insulation R-Values

Insulation Type: R-Value per Inch:
Fiberglass (loose) 2.2 – 2.9
Fiberglass (batts) 2.9 – 3.8
Cellulose (loose) 3.1 – 3.8
Stone Wool (loose) 2.2 – 3.3

What is the R-value of 2 inch fiberglass insulation?

Here are the R-values per inch of the most common types of insulation: Fiberglass (blown): 2.2 – 2.9. Fiberglass (batts): 2.9 – 3.8.

How thick is R20 fiberglass?

5.5-in
Johns Manville R20 Fibreglass Insulation Batts – Sound Barrier – 63.3-sq. ft. – 5.5-in Thick for 2 x 4 Walls.

What is the highest R-value for insulation on 2×4 wall?

Cavity insulation, like framing, has options. A 2×4 wall cavity can be insulated from R-13 to roughly R-25. A 2×6 wall can be insulated from R-19 to R-39.

What is the R-value of 3.5 inch fiberglass insulation?

The thicker the insulation, the higher its thermal resistance, or R-value. Standard 3.5-inch thick fiberglass insulation has an R-value of 11, and fits neatly in two-by-four wall stud spaces.

Can you squish fiberglass insulation?

When you compress fiber glass batt insulation, the R-value per inch goes up, but the overall R-value goes down because you have less inches or thickness of insulation. So, you don’t get the full R-value on the label, but the insulation still works perfectly well if all you’ve done is compress it.

What insulation has the best R-value per inch?

rigid foam panels
In the construction industry, how well a particular type of insulation resists the flow of heat is represented by a value called “R.” Among insulation types, rigid foam panels have the highest R-value per inch.

What is the R-value of 3 inches of fiberglass insulation?

2.2 per inch
An R-value is also calculated per inch of width. Therefore, a three-inch-thick board has an R-value of 3. Blown fiberglass installed in the attic has an R-value of 2.2 per inch, so 12 inches of it would give you an R-value of 26.4 in your attic installation project.

How do I know how much insulation I need?

To determine the amount of insulation needed, start by measuring the height and length of each of your room walls. Multiply the wall’s length by the wall’s height and don’t forget to write down the spacing of the studs so you can then determine what type of the insulation will be purchased.