Why sodium thiosulphate is used in titration?

Why sodium thiosulphate is used in titration?

Redox titration using sodium thiosulphate, Na2S2O3 (usually) as a reducing agent is known as iodometric titration since it is used specifically to titrate iodine. This absorption will cause the solution to change its colour from deep blue to light yellow when titrated with standardised thiosulfate solution.

How do you standardize iodine solution?

Iodine Solution Standardization Add 2 g of sodium carbonate, dilute with 50 ml of water and add 3 ml of starch solution. Titrate with the iodine solution until a permanent blue color is produced. Store in amber-colored, glass-stoppered bottles.

Why iodometric titrations are done quickly?

In these cases the titration of the liberated iodine must be completed quickly in order to eliminate undue exposure to the atmosphere since an acid medium constitutes an optimum condition for atmospheric oxidation of the excess iodide ion.

Why is potassium iodide used in titration?

KI, or potassium iodide, is used in iodometric titration because the iodide will be oxidized to iodine in the presence of an oxidizing agent.

How do you calculate normality of iodine?

for iodide solution 0.5M=0.5N and for iodine solution 0.5M=1N. how to prepare 0.5M/1N iodine solution? Dissolved 200g of KI in about 350 mL of ultra-pure water. Add 127g of iodine(I2) and mix until all the iodine crystals have dissolved.

How do you make iodine solution for titration?

Iodine solution: (0.005 mol L−1). Weigh 2 g of potassium iodide into a 100 mL beaker. Weigh 1.3 g of iodine and add it into the same beaker. Add a few mL of distilled water and swirl for a few minutes until iodine is dissolved.

How do you ensure a titration is accurate?

Terms in this set (9)

  1. Meniscus at eye level. To avoid parallax error.
  2. White tile. To see end point clearer.
  3. Remove funnel before titrating. Increases the vol making the titre smaller.
  4. Dropwise addition.
  5. No bubbles in pipette & burette at the tip.
  6. Swirling during titration.
  7. Few drops of indicator.
  8. Repeat the titration.

What are the possible causes of error in titration?

Several factors can cause errors in titration findings, including misreading volumes, mistaken concentration values or faulty technique. Care must be taken as the solution of the known concentration is introduced into a specific volume of the unknown through laboratory glassware such as a burette or pipette.

Why is the titration of arsenic and permanganate unsatisfactory?

I. INTRODUCTION It is well known that the direct titration of trivalent arsenic with permanganate in dilute acid solutions is unsatisfactory, because the reaction does not proceed according to stoichiometric relations. R.

Which is the best method to determine arsenic?

This method may be used for determining arsenic in the presence of antimony and tin. Satisfactory titrimetric methods are based on the oxidation of arsenious acid to arsenic acid by means of potassium iodate, potassium dichromate, potassium permanganate and ceric sulphate. The last two methods are of importance.

Which is the red precipitate of arsenic triiodide?

A hot solution of arsenious oxide or an arsenite in concentrated hydrochloric or sulphuric acid when treated with potassium iodide gives a red precipitate of arsenic triiodide. This reaction is quantitative if the iodine is removed by titration with thiosulphate.

How to determine the ratio of arsenite to arsenate?

To estimate arsenite and arsenate when present together, the former may first be determined in a portion of the solution by titration with iodine in the presence of sodium bicarbonate.