What is abend S213?

What is abend S213?

A S213-04 abend is caused by the disk dataset you are attempting to READ being unavailable. It can be caused by specifying the VOLSER that a dataset resides on and it is NOT on that volume. It can also be caused by the master catalogue.

What is IBM abend?

The ABEND macro is used to initiate error processing for a task. ABEND can request a full or tailored dump of virtual storage areas and control blocks pertaining to the tasks being abnormally terminated, and can specify that the entire job step is to be abnormally terminated.

What is s413 abend in JCL?

Explanation: The error occurred during processing of an OPEN macro instruction for a data set on magnetic tape or on a direct access device. This system completion code is accompanied by message IEC145I.

What is abend error?

An abnormal end or abend is an abnormal termination of software, or a program crash. This usage derives from an error message from the IBM OS/360, IBM zOS operating systems. Usually capitalized, but may appear as “abend”. The term is jocularly claimed to be derived from the German word “abend” meaning “evening”.

How do you resolve abends in soc6?

You resolve it the same way as any ABEND: find out where the problem occurred, figure out what happened to cause the specification error (hint: the manual will give you a list of possible reasons for many of the S0CX ABENDS), and then correct the issue.

How do you resolve abends in soc4?

How to Resolve S0C4? You can check if there are any un initialized indexes or subscripts in the program. You can check if the program is reading any file which is not opened. You can check if the LRECL matches with the length of file specified in file descriptor in COBOL.

What is abend aid mainframe?

Abend-AID is Compuware’s mainframe application failure resolution solution. Abend- AID combines ease of use with powerful fault analysis and diagnosis features to lead developers directly to the information they need to resolve faults and abends.

What did Abend s213-08 open macro for password protected dataset?

S213-08 An OPEN macro was issued for a password protected dataset but the system was unable to locate the password dataset. S213-0C An I/O error occurred reading a FORMAT 1 DSCB for a direct or indexed sequential dataset, or the FORMAT 1 DSCB could not be found on the volume specified by the DD statement.

Why do I get S213 Abend in my PDS?

BTW, when I get S213, it’s usually because the member isn’t there in the PDS I specified. Check to make sure the name of the member is actually what you think it is.

Where can I find the Abend reason code?

The abend reason code is the value of the S99ERROR code returned by dynamic allocation. Further information about the failure may be found in the job log. Contact technical support for assistance. I/O error. GTD CDIO