Can you have a receptacle above ceiling?
Receptacles are permitted above a suspended ceiling, but a flexible cord is not. Why install a receptacle above a ceiling if the flexible cord is not permitted in this space? Because the receptacle could be used for portable tools; it just can’t be used for cord-and-plug equipment fastened in place.
How close can an outlet be to the ceiling?
One electrician cited 5’6″ maximum above floor level for receptacles meeting the 6′ horizontal spacing rule (NEC 210-52) [4]. So you’d be OK with your high receptacle.
Can you have a junction box above drop ceiling?
There is no problem with installing junction boxes above a suspended ceiling, as long as the box is less than 100 in. ³ and securely fastened.
Can I running Romex above drop ceiling?
Registered. Romex cannot be run above drop ceilings except in residential work.
Can you put an outlet in the attic?
For attics and underfloor spaces, utility rooms, and basements, at least one lighting outlet containing a switch or controlled by a wall switch shall be installed where these spaces are used for storage or contain equipment requiring servicing.
What is code for electrical outlet spacing?
The US National Electrical Code, Section 210.52, states that there should be an electrical outlet in every kitchen, bedroom, living room, family room, and any other room that has dedicated living space. They must be positioned at least every twelve feet measured along the floor line.
What is code for junction box?
Article 334.30 states that cables coming out of the junction boxes should be secured within 12 inches of the box in all boxes equipped with cable clamps. These cable clamps are not to be removed. 314.17(C) states that cables must be secured to the receptacle box.
How do you support the wires above a drop ceiling?
Cables can then be attached to the catenary wire by means of metal clips and hangers, making sure that the cables are adequately supported throughout their length. Alternatively, metal cable tray could be used with metal cable clips fixed to the tray. Metal trunking is also another solution.
Is it OK to paint Romex?
Yes, but it doesn’t solve your problem. You can’t have exposed NM (Romex) cable like that. It needs to be behind the wall or in conduit. Even if you are on the right track, you will still get run over if you just sit there.
Can a receptacle be installed in a drop ceiling?
Yes you can install receptacles in drop ceilings and as long as the appliance is in accordance with the code like article 400.8 you have nothing to worry about.
Can You Fail an above grid ceiling inspection?
There is no time for a failed above-grid electrical inspection. Here are the 6 most common violations that inspectors see in an above-grid ceiling inspection: Ceiling tiles already installed. This is a big mistake made by the general contractor rather than the electrician.
Is it illegal to hang a power supply cord above a suspended ceiling?
Installing receptacles above a suspended ceiling is not prohibited by the NEC. However, leaving power supply cords permanently plugged in and hidden above the suspended ceiling is a violation of Sec. 400.12 (5).
Can a ceiling tile be installed without an inspection?
Never allow the ceiling tiles to be installed without asking the inspector first. Electrical boxes still open. Remember, since this could be the last time the inspector will see above the ceiling, the inspector wants to see that all boxes and openings are closed per NEC 110.12 (A).