When installing heating cable fasten the cable to the pipes using fiberglass tape or?

When installing heating cable fasten the cable to the pipes using fiberglass tape or?

Fasten the heating cable to the pipe at 1 foot intervals using SRK03 fiberglass tape or nylon cable ties. Do not use vinyl electrical tape, duct tape, metal bands or wire. 8. If there is excess cable at the end of the pipe, double remaining cable back along the pipe.

When should I turn my heat tape on?

The cables should be turned on when snow is expected – perhaps an hour or two before snow starts falling. This is true for both the zig zag style of installation or when radiant roof panels are used.

When installing temperature sensors in a pipe heat tracing system should the sensors be located?

Line sensors should be located at least 90 deg. (on the pipe) away from the heating cable so pipe temperature — not cable-sheath temperature — is measured. These sensors should also be located away from large heat sinks and placed at the coldest expected end of the heat tracing line.

What does easyheat ADKs roof and gutter heat trace cable do?

EASYHEAT ADKS roof de-icing cable prevents water and ice damage by providing a clear path for melting water. It keeps roof edges, gutters and downspouts ice-free. Versatile design adapts to most roof and gutter configurations.

Where to place heat trace cable on a roof?

The cable should be installed over the unheated portion of the roof (E in Fig. 1) – normally the roof area above the overhang. To design how much cable is needed, multiply the length of the roof edge that you want cable on by the following spacing factor: The overhang multiplier is the length of cable required per foot of roof length.

How does easy heat ADKs roof de-icing cable work?

Easy Heat ADKS roof de-icing cable prevents this water and ice damage by providing a clear path for melting water to flow off the roof. The versatile design adapts to most roof and gutter configurations. This product is intended for the sole use of preventing ice dams from forming on inclined roofs with tab shingles, in gutters and downspouts.

Where do I run the heat cable on my roof?

Take one end of the cable and begin at the corner of your roof. Run zigzags to create 15″ wide triangles, running the cable from the overhang to the warm area of your roof.

How do you tie a heating cable to a pipe?

Wrap EasyHeat HCA (optional Application Tape) or nylon cable ties at 6″ (15.24 cm) intervals to secure the heating cable to the pipe. • If the heating cable is the same length as the pipe, run it straight along the bottom of the pipe. If two cables are required, position them in the 4 and 8 o’clock positions.

What kind of thermostat does the easyheat cable use?

EH38 Preset Thermostat device allows cable to energize below 38°F and to turn off automatically at about 50°F. 1500 watt, 15 amp capacity. 125 Volts. For dry location s only.

How to test the easyheat roof deicing system?

Testing the system Once the installation is complete, apply power to the heating cable; wait about one hour, and then turn on a water tap supplied by the protected pipe and test the temperature of the water. It should feel warm almost immediately as the water heated by the cable flows through the pipe. Operation.