What does a pulse generator do?

What does a pulse generator do?

A pulse generator is either an electronic circuit or a piece of electronic test equipment used to generate rectangular pulses. Pulse generators are used primarily for working with digital circuits, related function generators are used primarily for analog circuits.

How does a high voltage pulse generator work?

A high voltage pulse generator is presented to drive Pockels cell. The Pockels cell behaves like a capacitor which slows the rise/fall time of the pulse and restrains the repetition rate of the generator.

What is gated mode in pulse generator?

External Gated Burst Mode: Output waveform is on or off, based on level of external signal applied to rear-panel Ext Trig connector. When the gate signal is true, the instrument outputs a continuous waveform. The noise waveform output stops immediately when the gate signal goes false.

How do you test a generator rotor with a multimeter?

Using a multi-meter set to test resistance, connect the multi-meter to each end of the wire coil using the leads. The meter should give a resistance measurement that is within the manufacturers specifications. A reading outside of this spec will indicate a bad winding. Perform this test on both power windings.

What is a high voltage pulse generator?

EHT pulse generators are designed to provide precision control over the output waveform to enable process optimization for research and industrial customers. They have been designed to drive plasma loads for medical devices, basic research, and semiconductor processing. …

When to disconnect the ignition pulse generator?

If the peak voltage measured at ECM multi-connector is abnormal, measure the peak voltage at the ignition pulse generator connector. Disconnect the ignition pulse generator 2P (Red) connector and conncct the tester probes to the terminal (Yellow and White/Yellow).

How to test the ignition system on a Honda CBR 600?

Crank the engine with the starter motor and read the peak voltage. If the peak voltage measured at ECM multi-connector is abnormal, measure the peak voltage at the ignition pulse generator connector. Disconnect the ignition pulse generator 2P (Red) connector and conncct the tester probes to the terminal (Yellow and White/Yellow).

What happens when you disconnect the ECM on a Honda CBR 600?

Faulty ECM (in case when the initial voltage is normal while disconnecting ECM connector) Initial voltage is normal, but it drops down to 2 – 4 V while cranking the engine. 1.

Where are the spark plugs on a Honda CBR 600?

Disconnect the direct ignition coils from the spark plugs (page 3-6). Connect the direct ignition coil 2P connectors to the direct ignition coil. Shift the transmission into neutral. Connect known-good spark plugs to the direct igni tion coils and ground the spark plugs to the cylinder head as done in the spark test.