What causes Onan generator to shut off?

What causes Onan generator to shut off?

Check the oil level in your generator when the oil level gets low it will shut down the generator. As the oil gets warmer it thins out just enough that it may fall below the proper level and shutdown the generator. Check the fuel filter for the generator as it may be restricting the amount of fuel getting to it.

How do I clear the code on my Onan generator?

How to Clear a Fault Code on Onan Generator

  1. Locate the primer button on the generator.
  2. Hold the primer button down for at least 30 seconds.
  3. Release the button and start the generator.
  4. Allow the generator to run for 15 minutes, to ensure that the code has cleared.

What does it mean when my Onan generator blinks 3 times?

Should your Onan generator light blink 3 times in a row, it shows a service shutdown, and you will require secondary Onan generator troubleshooting codes from your generator. Press the Prime button once to prompt a second, two-digit fault code.

Where is the reset button on a Onan 4000 generator?

How do I reset my Onan generator?

  1. Locate the primer button on the generator. It is located on the side of the unit, below the gas tank.
  2. Hold the primer button down for at least 30 seconds.
  3. Release the button and start the generator.
  4. Allow the generator to run for 15 minutes, to ensure that the code has cleared.

How long do I prime my Onan generator?

Hold the prime button in for 30 seconds or even longer if the fuel line is empty so that the pump has time to deliver fuel to the carburetor and fill the float bowl.

What is code 3 on a Onan generator?

The fault code 3 on your Onan QG 5500 generator means that your generator has stopped or is refusing to start due to one of the other 29 possible second-level two-digit fault codes.

What do you do when your RV generator won’t start?

If your generator is acting strange or won’t start, checking the oil should be one of the first things you do. Although generators run on standard motor fuel, not all of them use the same kind. If the oil is low, check your RV owner’s manual to see what type of oil you should use in the generator.

When does the Onan generator shut down code 36?

Onan Generator Code 36 Generator Runs For a Few Minutes Then Stops Onan Generator Stops Running When Hot Diagnosing Different Onan Generator Issues Error Code 36 Advice Some Final Words It is possible for your Onan generator to start up fast and quit just as quickly.

What does the code 3-service check mean Onan generator?

Code 3 – Service Check When you see this code, it indicates that there is a problem somewhere on your Onan generator. You will get 3 flashes then a pause, then 3 flashes, then a pause and on it goes till you press the button to get the secondary code. The secondary code will give you the specific problem that is wrong with your generator

What does code 12 over voltage on Onan mean?

Code 12 – Over Voltage This problem comes from a faulty inverter and that part is overcharging the generator. The only way to solve this Fault Code problem is to take the generator to a qualified Onan dealer or repair shop. Alternative sources for this code may be a lack of fuel or a clogged filter problem.

What happens if you blink on Onan generator?

If you blink you may miss it. That may be a bad pun, but it is the truth when it comes to Onan generators. When something goes wrong, the generator will send out a code to tell you the problem. If you blink, you may miss the number of the error code.