How does a 4-20 mA output work?
The 4-20 mA current loop has been the standard for signal transmission and electronic control in control systems since the 1950’s. In a current loop, the current signal is drawn from a dc power supply, flows through the transmitter, into the controller and then back to the power supply in a series circuit.
What is the voltage of a 4-20 mA signal?
Since our industry has standardized on a shunt value of 250 Ohms, “v” will range between 1 and 5 volts for a 4-20 mA current loop signal (v=i * resistance).
What is a 4-20 mA communication?
A 4–20 mA current loop is a means to pass a “value” like flow using an established electrical current (the loop) as the carrier of this information. Typically, the 4 mA depicts the minimum/low value (like 0 for flow); and the 20 mA depicts the maximum/high value, or full scale, of the value that is sent.
How do transmitters work?
The transmitter combines the information signal to be carried with the radio frequency signal which generates the radio waves, which is called the carrier signal. This process is called modulation. The information can be added to the carrier in several different ways, in different types of transmitters.
How do I check my mA?
Access the signal wires (typically by removing the cover on transmitter). Select the mA dc measurement function and connect the test leads for mA measure. Locate the mA signal wire, disconnect one lead of the signal wire and put the meter in series with the mA signal wire and view the mA measurement.
What is a 4-20 mA transmitter?
4-20 mA Transmitter A transmitter is a transducer that responds to a measured variable by means of a sensing element and converts it to a standardized transmission signal (like 4-20mA) that is a function only of the measured variable. Transmitters can have any of several electrical connection schemes.
How long can a 4-20 mA loop be?
about 18,750 feet
20G conductors at about 12 ohms per 1000 feet (about 330m) means that 450 ohms of 20G conductor could be support 4-20mA as far as about 18,750 feet, about 3.5 miles or about 6km.
How do you test a 4-20 mA signal?
Access the signal wires (typically by removing the cover on transmitter). Locate the mA signal and zero the mA clamp meter. Verify the mA measurement, should be between 4 and 20 mA. This measurement technique does not interrupt (break) the loop to measure the 4 to 20 mA signal.