When should you use a gas shut off valve?

When should you use a gas shut off valve?

When to turn off your gas In an emergency, your gas can be turned off at the main gas service shutoff valve. Do not shut off the gas unless you smell gas, hear gas escaping, see a broken gas line or suspect a gas leak.

Does each gas appliance need a shut off valve?

G2420. 5 (409.5) Appliance Shutoff Valve. Each appliance shall be provided with a shutoff valve in accordance with Section G2420. 5.1, G2420.

What should you do when there is no shut off valve on a gas system?

If you do not have a house-side valve, or if your house-side valve is not working, you can operate the street-side valve using a 12-inch or larger adjustable wrench. Turn the valve a quarter turn in either direction so that the valve sits crosswise, or perpendicular, to the pipe.

What tool is needed to shut off a main gas valve?

Take a 12-inch or larger adjustable wrench, and turn the valve 1/4 turn in either direction, until the valve is crosswise to the pipe. (See Diagram B) TIP: Keep a 12-inch or larger adjustable wrench with your emergency supplies, or next to your valve.

How do I know if my gas valve is off?

When the long side of the nub or handle is parallel to the incoming gas line, it’s open and the gas is flowing. When it’s turned a quarter turn, perpendicular to the incoming pipe, it’s closed.

How far can a gas valve be from the appliance?

Building codes now require the gas shutoff valve to be located within 6 feet of the appliance and in the same room. If you find an improper situation that doesn’t meet the code requirements, it’s a good idea to have a service person install a proper shutoff valve.

How do I shut off my gas supply?

The shut-off valve for your gas supply is normally near your gas meter. It’s a good idea to know where it is in case there’s an emergency. Give the handle a quarter turn in either direction to switch it off. The valve is closed when the handle is at a right angle to the pipe.

How do you turn off the gas in case of an emergency?

There is a shut-off valve running parallel with the pipe, usually located about 6 to 8 inches above the ground. Take a 12-inch or larger adjustable wrench, and turn the valve 1/4 turn in either direction, until the valve is crosswise to the pipe.

Are gas valves directional?

They are non directional. Choose your direction from which way you want the valve to turn to operate it.

When do you need a gas shut off valve?

“When gas is provided by a central system, an emergency shut-off valve, activated by pushing a highly visible visible button, will be needed. A central control valve can enable the teacher to shut off the gas in the room when not in use.

What is the hkps01a gas emergency shut off valve?

HKPS01A solenoid valve are emergency automatic shut-off solenoid valves for gas line. They are safety apparatus used in gas pipeline cut-off at an emergency.

What is an emergency shut off solenoid valve?

This feature meets safety regulations in the event of an accident. HKPS01A solenoid valve are emergency automatic shut-off solenoid valves for gas line. They are safety apparatus used in gas pipeline cut-off at an emergency.

What do you need to shut off gas in California?

Use an approved valve. The State of California requires approval for all excess flow gas shut-off valves and earthquake-actuated gas shut-off valves used within the state. A list of approved valves is available. Visit DSA Gas Shut-off Valves Certification Program.

https://www.youtube.com/watch?v=lLfnK21WOs8

Posted In Q&A