What happens if the blower motor only works on high speed?

What happens if the blower motor only works on high speed?

In other designs, the failure of 1 resistor means you lose only one speed. However, most car makers bypass the blower motor resistor completely when you move the fan speed switch to high. If your blower only operates on its highest speed, chances are you have the series type of blower motor resistor. This is the most common failure mode.

What causes a blower fan to not work?

When this happens, you may notice that you will not feel anything blowing out of the vents at all. This may also cause the blower motor to work intermittently. A blower fan is connected to the negative battery terminal (also called ground) on one end and to the positive battery terminal through a blower motor resistor on the other end.

Why is the resistor not working on my blower?

Hi There, The resistor is what controls the speed of the blower motor, not the relay. The blower motor relay supplies power to this motor when you turn the switch to “on” that can sometimes fail. When this happens, you may notice that you will not feel anything blowing out of the vents at all.

Why is my blower motor only working at high speed?

The first thing that needs to be determined is the type of noise that is present and the possible sources. Rattling or knocking noises while… The blower motor only working on high speed is a common symptom of a failing blower motor resistor; but the fact the radio stopped working at the same time is unusual.

Hi There, The resistor is what controls the speed of the blower motor, not the relay. The blower motor relay supplies power to this motor when you turn the switch to “on” that can sometimes fail. When this happens, you may notice that you will not feel anything blowing out of the vents at all.

What to do if your climate controlled blower wont shut off?

If your climate controlled blower processor is shot, be prepared to spend mucho bucks for a replacement. But before you start throwing expensive parts at the problem, you’ll have to do some checking. Start by testing the gray/black wire at the blower motor control processor. First, try grounding the wire. Then try removing it.

How does the processor work on a blower motor?

The processor is what lets you select and infinite range of blower speeds. In vehicles without climate control, you’ve only got three blower speeds and those are controlled by a blower motor relay.

How is a blower fan connected to a battery?

A blower fan is connected to the negative battery terminal (also called ground) on one end and to the positive battery terminal through a blower motor resistor on the other end. The blower resistor is connected in series to the blower fan motor.

What’s the problem with my blower motor fan speeds?

Probably a bad blower motor resistor you have there, or possibly a faulty blower motor or switch. The most common thing would be the resistor assembly, as that goes out more often than the other parts. A quick check with a test light can determine failure. No Heat In My 2000 Chevrolet Malibu – Blower Not…

Why does my car AC only work on high speed?

Into why your car AC only work on high speed. what is a blower motor resistor? Blower motor resistors are used to control the fan speed of automotive blowers motor. The fan speed can be changed either by switching the blower resistor resistance mechanically, or by using the main AC switch, and also electronically by the air conditioning system.

How does an air conditioner change the fan speed?

Blower motor resistors are used to control the fan speed of automotive blowers motor. The fan speed can be changed either by switching the blower resistor resistance mechanically, or by using the main AC switch, and also electronically by the air conditioning system.

Why is my blower motor resistor not working?

CLICK HERE TO RESET YOUR PASSWORD! Help! Fan quit working on all 4 speeds. AC light & recirc light still light up and AC compressor clutch engages when turning fan on in AC mode, but not getting the fan to work. I replaced the blower motor resistor and the control unit with new parts from rockauto (ACDelco).

How can you tell if a car fan is going bad?

As this happens, it means the motor won’t be able to push as much air through your vehicle’s HVAC system, so you’ll start to notice that the blowers aren’t nearly as powerful as they once were. You might also notice that the fan works at some speeds, but not at others, or that once you reach a certain speed the fan doesn’t work at all.

How does a blower motor resistor control the fan speed?

The blower motor resistor controls the fan speed of the blower motor and the resulting change in air pressure produced by the movement of the blower fan. It accomplishes this by regulating the electric current that powers the motor.

What happens when the a / C fan is on the highest setting?

When the a/c fan is on any setting other than the highest setting the air comes out cold. When the fan is set to the highest setting, it only comes out warm. This happens regardless of a/c or max a/c setting, regardless …

In other designs, the failure of 1 resistor means you lose only one speed. However, most car makers bypass the blower motor resistor completely when you move the fan speed switch to high. If your blower only operates on its highest speed, chances are you have the series type of blower motor resistor. This is the most common failure mode.

When to use a blower instead of a fan?

Blowers are used in situations where the system resistance is higher than that for a fan. It helps to picture a blower as a device that needs to move a gas through a resistance, such as ducting, which obviously has a much higher system resistance than just the cage on a fan.

When the a/c fan is on any setting other than the highest setting the air comes out cold. When the fan is set to the highest setting, it only comes out warm. This happens regardless of a/c or max a/c setting, regardless …

Why does my Ricks free auto blower motor not work?

A clogged cabin air filter reduces airflow through the ducts, increases current draw on the blower motor and can cause blower motor resistor overheating and premature failure. If you replace the resistor and it burns out again, check the current draw on the blower motor.

What are the resistors on a blower motor?

Blower resistors are made of several resistors with different resistances. There are also two additional circuits used for the off state of operation as well as the highest speed of operation. In the off state, the blower motor is effectively disconnected from the power supply.

A clogged cabin air filter reduces airflow through the ducts, increases current draw on the blower motor and can cause blower motor resistor overheating and premature failure. If you replace the resistor and it burns out again, check the current draw on the blower motor.

What are the symptoms of a failed blower motor resistor?

Blower motor resistor problems. Problems with a blower motor resistor are common in many cars. The most common symptom of a failed blower motor resistor is when the heater fan only runs at high speed and doesn’t work at low speeds.

Do you need a blower motor resistor harness?

Replacement AC Blower Motor Resistor Kit With Harness – Controls the fan speed in your AC and heating system. If you can no longer adjust the air speed with your AC controls or your AC system no longer blows chances are you need a new Blower Motor Resistor. This COMPLETE KIT includes the Blower Motor Resistor and New Wire Harness.

How much does it cost to replace a blower motor resistor?

The blower motor resistor or control module replacement is not very expensive. For example, one of our colleagues had a problem with his 2011 Ford Escape: the fan only worked at the speed 4. He paid $50 to diagnose and $112 to replace the resistor at a local Ford dealership.

How to choose the right air conditioner blower motor?

In order to get the right blower motor for your air-conditioner, the contractor has to take a number of things into consideration, including the type of drive, the diameter of the motor, rotation direction, horsepower, voltage, speeds, and size of the capacitor.

How can I tell if my blower motor is faulty?

This is usually the first indication that you may have a faulty blower motor. If the airflow coming out of the vents is weak, it can mean that your blower motor is having a hard time pushing enough air through the ducts to achieve your desired temperature.

Why does my HVAC blower motor keep overheating?

Your blower motor may overheat because of a number of reasons. Dirt and grime can accumulate around the motor and prevent it from venting itself, causing heat to build up over time. You can solve this problem by hiring a professional to service your motor. Sometimes, age is the biggest threat to an HVAC system.

In order to get the right blower motor for your air-conditioner, the contractor has to take a number of things into consideration, including the type of drive, the diameter of the motor, rotation direction, horsepower, voltage, speeds, and size of the capacitor.

What are the symptoms of a bad blower motor relay?

3. Melted relay. Another more serious symptom of a problem with the blower motor relay is a burned or melted relay. Relays are exposed to high current loads and can sometimes get hot when they develop problems.

Why does my blower fan spin at a certain speed?

It send a certain amount of voltage to the motor to have it spin at the requested speed you select on the control head. To do this, there are resistors built into the unit to control the voltage. If you are not familiar with how electricity works, basically it comes down to this…resistance causes heat.

Is there a high speed blower motor relay?

Yes there is a high speed relay which sounds like it is out. Here is a guide to help test it and the blower motor wiring diagrams so you can see how the system works with the relay location below as well. Check out the diagrams (Below).

What’s the best speed for an AC blower?

Because this process is complicated, working with an expert in AC repair and maintenance is a worthwhile venture. What is the Recommended Speed for Your Blower?

Can you change the speed of an air blower?

Yes you can but we think its just better to know that it can be done whats involved with a simple speed change of your air blower for your furnace air conditioner or heat pump. Ryan from Environmental Heating & air of nc gives you the color codes and speed of those wires.

Yes there is a high speed relay which sounds like it is out. Here is a guide to help test it and the blower motor wiring diagrams so you can see how the system works with the relay location below as well. Check out the diagrams (Below).

Because this process is complicated, working with an expert in AC repair and maintenance is a worthwhile venture. What is the Recommended Speed for Your Blower?

Why does my Jeep Wrangler fan only work on high?

Knows a couple things… The fan only working on high is normally due to a defective resistor pack. The resistor pack is used for all speeds except for the fan’s highest speed where the resistor pack is bypassed. Your 2003 has it in a different location than my ’97 does but yours should be somewhere up above the passenger side footwell.

Where do I replace the resistor on my blower motor?

To repair the problem, simply replace the resistor block. It’s usually located in the ductwork (to keep the coils cool) below the glove box. Unplug the electrical connector, remove the screws and replace the unit. Replacement blower motor resistor blocks are usually available from any auto parts store or the dealer.

Why is my HVAC blower running very slowly?

Typically Red=Low, Blu=Med, Blk=High. The black lead is usually the one needed for a/c operation. Sometimes the motors wear out by having the lubricant in the bearings go dry. In this case the blower wheel will not turn effortlessly and smoothly by hand when the unit is off. If the bearings are dry, then you need a new blower motor.

If there is power indicated on high blower speed, but not low or mid range, the problem is the blower resistor. Test for ground at the blower motor if there is power indicated at all ranges, but the motor does not function.

How can I tell if my blower speed switch is faulty?

Test for power at all the blower speeds by moving the blower speed switch through all positions. A faulty resistor loses power at different positions on the switch. High blower speed has direct power to the motor from the switch. If there is no power indicated on high blower speed, the problem is most likely the switch or the fuse.

Why does my blower only work on high speed?

If your blower only operates on its highest speed, chances are you have the series type of blower motor resistor. This is the most common failure mode. To repair the problem, simply replace the resistor block.

How does a half speed blower motor work?

So a half speed driver request will result in the blower motor controller pulsing the ground connection off twice as often as when the fan is running at full speed. Carmakers use these three common wiring methods to supply power and ground to the blower motor in a manual system using a blower motor resistor.

Why does my heater not work on high speed?

Heater blower motor will not work on high speed? I have replaced the black bosch relay behind the glovebox, the blower resistor and the blower motor and still cannot get the blower to work on high. I remember in older model years of gmc’s and chevys that their was a high speed blower relay that caused this issue.

Blower motor resistor problems. Problems with a blower motor resistor are common in many cars. The most common symptom of a failed blower motor resistor is when the heater fan only runs at high speed and doesn’t work at low speeds.

What should I do if my blower motor stops?

Replace blower motor. If you have a variable speed blower motor, replace the blower motor speed control module. If you have a three or four speed blower motor, remove the blower motor relay. If the motor stops, replace the relay. Alldatadiy.com and Eautorepair.net are professional-grade shop manuals—period.

What do you need to know about blower motor fan?

Diagnostic training videos and content hosted by ASE Master and L1 Certified Technicians. Our goal is to teach you ways to be quicker and more efficient in your diagnosis by implementing different techniques and tools. Rich Condition Diagnosis…Or Is It?!

Replace blower motor. If you have a variable speed blower motor, replace the blower motor speed control module. If you have a three or four speed blower motor, remove the blower motor relay. If the motor stops, replace the relay. Alldatadiy.com and Eautorepair.net are professional-grade shop manuals—period.

To repair the problem, simply replace the resistor block. It’s usually located in the ductwork (to keep the coils cool) below the glove box. Unplug the electrical connector, remove the screws and replace the unit. Replacement blower motor resistor blocks are usually available from any auto parts store or the dealer.

Where is the blower motor on a Mercedes Benz?

The motor can be seen hanging down close to the passenger kick panel. Just to the left of the blower motor, an electrical connector connected to a flat 1-inch-by-2-inch plate can be seen. This is the blower motor resister, which controls the fan speeds. Disconnect the multi-wire connector from the blower motor resister next to the blower motor.

What to do if your blower is not working?

The very first step you need to take is getting a scan run on the computer. Take your car to a technician or a local parts store and have them scan the car. They will give you a list of… Hello there, thank you for asking about your 1998 Oldsmobile LSS.

How do you test for ground at the blower motor?

Test for ground at the blower motor if there is power indicated at all ranges, but the motor does not function. Most blower motors ground through the case of the motor when it is screwed into place or by a small ground strap from the case to the body of the car.

What should I do if my blower wont shut off?

If the blower stops with either of these steps, the problem is in the HVAC control module. However, if the blower continues to run at high speed with either of those tests, replace the blower motor control processor. Just as an FYI, the retail price of the blower motor control processor is $280.34.

Where does the ground go in a Honda blower motor?

The blower motor control module (Honda calls it Power Transistor) supplies the ground. The power transistor has 4 wires: two come from the climate control system control unit, one is the ground, one goes to the negative terminal of the blower motor.

The blower motor control module (Honda calls it Power Transistor) supplies the ground. The power transistor has 4 wires: two come from the climate control system control unit, one is the ground, one goes to the negative terminal of the blower motor.

How to prevent repeat failures of blower motor fan?

Plus – Tips To Prevent Repeat Failures! If playback doesn’t begin shortly, try restarting your device. Diagnostic training videos and content hosted by ASE Master and L1 Certified Technicians. Our goal is to teach you ways to be quicker and more efficient in your diagnosis by implementing different techniques and tools.

Diagnostic training videos and content hosted by ASE Master and L1 Certified Technicians. Our goal is to teach you ways to be quicker and more efficient in your diagnosis by implementing different techniques and tools. Rich Condition Diagnosis…Or Is It?!

What is the function of a blower motor resistor?

Jan 8th 2016 at 6:32PM. The blower motor resistor is an electrical component that is a part of the vehicle’s heating and air conditioning system. It is responsible for controlling the blower motor’s fan speed.

What happens when you lower the blower speed of a forced air furnace?

The blower energy draw at a lower speed will be offset by the loss in fan wheel inertia. But you will have a tough time measuring either on your basement Trane.

Where is the blower control switch on the dashboard?

The blower control switch on the dashboard controls the circuit flow of the blower motor to adjust the voltage from low, to medium, to medium-high, to high. When on high, the circuit bypasses the blower resistor.

Is the blower motor on a Chevy Silverado working?

Blower Motor does not work on 1 and 2 speed chevy silverado – YouTube I had a Bad Relay. I got one here https://amzn.to/2PSr6fQ It seems the 88-94Trucks have a different system to control the speeds than the 96-00 OBS style Ch…

Why is the blower motor not working on my car?

My car has an automatic transmission. Hi There, The resistor is what controls the speed of the blower motor, not the relay. The blower motor relay supplies power to this motor when you turn the switch to “on” that can sometimes fail. When this happens, you may notice that you will not feel anything blowing out of the vents at all.

How does a 3 speed blower motor work?

Older style blower motor resistor with exposed resistor elements. The blower motor resistor is what’s responsible for giving you three blower speeds. The resistor block contains three different high resistance coils. Think of these coils like a filament in a light bulb.

Where is the fuse on a blower motor?

Locate the fuse for the blower motor in the owners/service manual. Test the fuse, with the ignition key on, using the 12-volt test light.

Why does blower only work on high only?

A bad blower motor resistor can cause your blower works on high speed only. Older style blower motor resistor with exposed resistor elements. The blower motor resistor is what’s responsible for giving you three blower speeds. The resistor block contains three different high resistance coils.

Why does the blower fan only work on high speed?

The fan only working on high is normally due to a defective resistor pack. The resistor pack is used for all speeds except for the fan’s highest speed where the resistor pack is bypassed.

Is my blower motor bad?

No air from the vents. No air flow from the vents when the heater or air conditioning is activated is another symptom of a bad blower motor. If the heater blower motor burns out or short circuits, it will not function, and therefore will not be able to produce any airflow for the system. The blower motor will usually have to be replaced in order…

Is there a way to test a blower motor?

Blower Motor Resistor Testing Place one lead of the Ohmmeter on terminal 1 of the resistor. Place the other lead on terminal 2 and check against specifications. Move the lead from terminal 2 to terminal 3 and check this reading against specifications. Move the lead from terminal 3 to terminal 4 and check this reading against specifications.

Blower resistors are made of several resistors with different resistances. There are also two additional circuits used for the off state of operation as well as the highest speed of operation. In the off state, the blower motor is effectively disconnected from the power supply.

Can a blower be used for heating and a / C?

Depending on your local conditions, it is possible that heating and a/c can utilize the same blower speed. Too low a speed will cause freezing (no good)in a/c. The temperature rise in heating (difference between supply and return temperatures) must be within specifications.

Where is the blower fan on a Nissan Frontier?

Looks like it’s under the dash, towards the left side of the middle area. The cooling/heater unit is right above the ducts that come out in the middle under the dash. So, I’m guessing the resistor is somewhere in the vicinity up above the gas pedal.


When this happens, you may notice that you will not feel anything blowing out of the vents at all. This may also cause the blower motor to work intermittently. A blower fan is connected to the negative battery terminal (also called ground) on one end and to the positive battery terminal through a blower motor resistor on the other end.



Why does my Volvo 740 make a hissing sound?

Leaking Sound from Heater Controls. [John Sargent] One of my 740s made a hissing sound from under the dash in the area of the heater temperature control lever. The manual heater control assembly supplies vacuum to the under hood heater valve to shut off coolant flow to the heater core in the cold position of the control lever.