How is the installation of an EnCon thermal evaporator done?
Installation of the ENCON Thermal Industrial Wastewater Evaporator is very straight forward and is generally handled by facilities, maintenance or plant engineering personnel. Primary connections include plumbing from the holding tank, sump, or pit to the feed pump and/or inlet valve.
How are thermal evaporators installed in a building?
Stacks of varying materials (galvanized, stainless, or CPVC) are easily fitted over the blower exhaust outlet. The stack is typically installed vertically through the ceiling but can also be run at an angle to a nearby wall then run vertically up the side of the building.
What kind of power do you need for an EnCon evaporator?
Finally, electrical power is run to the auxiliary control panel on the rear of the evaporator. Single phase, 110 VAC power is required for units 8-72 gal/hr (excluding electrically heated systems which require either 240 or 480 VAC, three phase power) and three phase, 240 or 480 VAC power is required for units rated 96-400 gal/hr.
Where is the inlet valve on a thermal evaporator?
Then from the pump and/or inlet valve to the 1″ NPT inlet located on the lid of the evaporator. Other optional plumbing includes hard piping with a manual ball valve from the fitting on the residue clean out flange to a residue holding tank as well as providing a nipple and manual ball valve to allow for decanting of free oil to a drum.
How do you install a refrigerant evaporator system?
Connect all Piping. Next, connect all refrigerant piping so that you can perform an evacuation while the remainder of the installation is completed. If a distributor nozzle is required, insert the correct one into the distributor followed by the expansion valve, before completing piping.
Installation of the ENCON Thermal Industrial Wastewater Evaporator is very straight forward and is generally handled by facilities, maintenance or plant engineering personnel. Primary connections include plumbing from the holding tank, sump, or pit to the feed pump and/or inlet valve.
When to install a P trap on an evaporator?
On a single evaporator, install the solenoid valve before the expansion valve. A suction line āPā trap will always need to be installed if at any time the suction line becomes a riser that goes up above the evaporator. 6. Clamp TXV Bulb to Line.
Where to remove the evaporator from a car?
This operation should be performed by a licensed refrigerant handler. Remove the liquid line connection that goes to the evaporator, and then remove the heater hoses from the core. Next, remove the air conditioning and heating unit from under the dashboard, which is located under the instrument panel.