What is event ID 5010?

What is event ID 5010?

Event ID – 5010 The process id was ‘%2’. Event Information. According to Microsoft : Cause : This event is logged when a process serving application pool failed to respond to a ping.

What is shutdown time limit application pool?

1 Answer. 1. The shutdown time limit hint leaves the old worker process running for up to the number of seconds indicated. If all requests are completed prior to that time, then it will shut down earlier. When recycling happens, a new worker process spins up and immediately begins taking new requests.

Is a process serving application pool failed to respond to a ping?

When you see an event such as “A process serving application pool ‘appPool’ failed to respond to a ping.” means the process is in dead state. Rapid fail protection is the recycling option which takes care of such issue and recycles the appPool on it’s own to such that it maintains good health of the worker process.

Why app pool recycle is required?

What is Application Pool Recycling in IIS? Recycling means that the worker process that handles requests for that application pool is terminated and a new one is started. This is generally done to avoid unstable states that can lead to application crashes, hangs, or memory leaks.

How do I disable app pool recycling?

On your Web Server machine(s), open Internet Information (IIS) Services. In the IIS tree, expand the current machine and select Application Pools. Select RepositoryAppPool and click “Recycling…” hyperlink from the right hand menu. Uncheck all boxes (by default, “Regular time intervals (in minutes)” option is selected)

How do I ping an application pool using IIS?

Click the “Application Pools”. Perform for each Application Pool. Highlight an Application Pool to review and click “Advanced Settings” in the “Actions” pane. Scroll down to the “Process Model” section and set the value for “Ping Enabled” to “True”.

What is rapid fail protection in IIS?

Rapid fail protection is a feature that interrogates the health of worker processes associated with websites and web applications. It can be configured to perform a number of actions such as shutting down and restarting worker processes that have reached failure thresholds.

What does restarting app pool do?

You usually recycle your application pool to get rid of leaked memory (you might have a problem in your application if this needs to be a regular operation, even though it is recommended to have a scheduled recycle). As for restarting a website, it just stops and restarts serving requests for that particular website.

What happens when app pool recycle?

When you recycle an application pool, IIS will create a new process (keeping the old one) to serve requests. Then it tries to move all requests on the new process. After a timeout the old process will be killed automatically.

What is the event ID for Microsoft Windows was?

Event Id: 5010: Source: Microsoft-Windows-WAS: Description: A process serving application pool ‘%1’ failed to respond to a ping. The process id was ‘%2’. Event Information: According to Microsoft : Cause : This event is logged when a process serving application pool failed to respond to a ping. Resolution : Diagnose an unresponsive worker process

Where is event ID 5010 from netwlv64?

The description for Event ID 5010 from source netwlv64 cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.

What is the event ID for a failed Ping?

Event ID – 5010. A process serving application pool ‘%1’ failed to respond to a ping. The process id was ‘%2’. This event is logged when a process serving application pool failed to respond to a ping. Ping failure.

Why is my event log not saved on my computer?

Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer. If the event originated on another computer, the display information had to be saved with the event.