Why is my international 4300 DT 466 AC not working?
Im working on another ac, 2005 international 4300 dt 466 we replaced 3 major ac hoses, orfice tube, high pressure sensor and recharged the system as international specs. Well we started the system and is not blowing cold air, is 85f inside cab. Did we missed anything
How tall is the 2006 International 4300 truck?
2006 international 4300 dt 466 diesel 24′ box 102″ wide 103 ” inside tall, gail gate, this is a very clean truck . Come and check this truck out .
Why does my international 4300 engine not start?
Replaced injector, put new orings on hipop. It will not start. Runs on ether but dies as soon as ether stops. Replaced both batteries. Checked fuses by batteries. All good. We pulled the ipr and bench tested it. It was working. Scanner says 8 engine codes. They are: FMI=4 VOLTAGE BELOW NORMAL OR SHORTED TO LOW SOURCE.
What’s the oil pressure on an international 4300?
SPN175 ENGINE OIL TEMP. SPN 102 BOOST PRESSURE. FMI= 4 VOLTAGE BELOW NORMAL OR SHORTED TO LOW SOURCE. SPN 100 ENGINE OIL PRESSURE. FMI= 3 VOLTAGE ABOVE NORMAL OR SHORTED TO HIGH SOURCE. SPN105 INTAKE MANIFOLD TEMP.
Is there no power to an A / C compressor?
No power to a/c compressor, I have checked the fuses, relays and freon. Clicking this will make more experts see the question and we will remind you when it gets answered. You can’t post conmments that contain an email address.
When to turn on the a / C compressor in a truck?
Once the pressure is about 300 psi it will tell the engine to turn the fan on. If the a/c pressure continues to rise over about 350 the body controller will log an a/c high pressure fault which will lock out the a/c operation until the next key cycle. Does your fan come on at all?
How to get Freon Flash codes on 2006 International 4300?
Freon is suppose to be 1.8 lbs. To get the flash codes key on set park brake , on the steering wheel, left side steering wheel cruise top button, right side steering wheel cruise bottom button; hold those 2 together, that will start the flash codes. Toggle with odometer button, give me codes exactly as they read on dash.
Where does the air come from on an international 4300?
I’ve got an 05 4300 and the air is only coming out of the vents. I checked all the fuses and breakers in the cab fuse panel and they all check out.
What should the high pressure switch be on an international 4300?
Sounds like the high pressure switch is bad. The high side should go up close to 300psi before it cuts the compressor off. The normal opperating range for the high side is 180-250 and your not getting that.
How much Freon does an international 4300 hold?
PUT TWO NEW THERMISTERS IN IT,part #3622764c3 and if its a two door cab it should hold 2 lbs of freon and if its a extra cab it should hold 2.25 lbs.hope this helps.
How many Freons are in a Ford truck?
Technical Service Information International Trucks Simplefooe Ford Refrigerant And Oil Capacity Charts Kenworth Hvac Systems International Truck Freon Capacity Chart Pflag Hybrid Electric Vehicle Air Conditioning Pressor Hardware Power Controls Diagnostics Heavy Duty Air Conditioning Service Manual
How many ounches are in a freon tow411?
Wait for a good hot day and charge by pressures or call an international dealer parts department with your vin they will tell you right away. i’m pretty sure it is 30 ounches.dealor couln’t tell me either.if you over or under charge them the check ac light will come on.this what we charged our 4300 at last year and it worked fine.
What’s the normal opperating range for a 4300?
The normal opperating range for the high side is 180-250 and your not getting that. yes the cabin air filter was changed at the same time as the orifice tube and accumulator (about 4k miles ago). would a bad high pressure switch kick it off at a lower psi and be consistent about it?
Is the mode actuator still good on the International 4300?
Thanks for the responses guys, it was the mode actuator. The motor is still good but the plastic housing over the shaft broke. At least I was able to move the air down to the floor for now and keep from getting blown in the face.
Is there way to reset’check a / c’light on IH 4300?
The ‘Check A/C’ light is on in my 2005 4300 International. Is there a way to reset that light, or find out if there are any ‘codes’ as to why it’s on?
What’s the oil pressure on a 2006 International 4300?
SPN175 ENGINE OIL TEMP. SPN 102 BOOST PRESSURE. FMI= 4 VOLTAGE BELOW NORMAL OR SHORTED TO LOW SOURCE. SPN 100 ENGINE OIL PRESSURE. FMI= 3 VOLTAGE ABOVE NORMAL OR SHORTED TO HIGH SOURCE. SPN105 INTAKE MANIFOLD TEMP. FMI= 4 VOLTAGE BELOW NORMAL OR SHORTED TO LOW SOURCE. SPN 94 FUEL DELIVERY PRESSURE.
Is the DT466 4300 an Allison Transmission 20 code?
You I have a 2003 international dt466 4300 flatbed with You I have a 2003 international dt466 4300 flatbed with Allison transmission 20 codes showing … read more Andy
What’s the problem with my international AC system?
Discussion in ‘ International Forum ‘ started by IanG, Sep 26, 2015 . 02’ 9200i, all new ac system, worked great and now have lost electric power all way from the compressor to the relay behind glove box. All of the other relays and fuses have power and are working except for this one.
Can a 04’international 4300 truck repair work?
Truck Repair This answer was rated: HI, I have an 04 international 4300. A/C will not work. the… HI, I have an 04’… HI, I have an 04′ international 4300.
Are there any problems with the International 4300?
International 4300 owners have reported 11 electrical system related problems since 1996. Table 1 shows the 5 most common electrical system problems. The number one most common problem is related to the vehicle’s electrical system (6 problems).
What’s the price of a 2006 International 4300?
Stock #rc125613 2006 international 4300 box truck with 24′ dry van body. Just in, getting inspected. Asking $7900 or best offer. Each vehicle undergoes a 70 point pre-sale inspection and comes with a maintenance history report.
How to reset a / C on International trucks?
You can by pass each of the 2 thermistors with a 1500 ohm 1/2 watt resistor at the harness plug. Without Diamond Logic you can not monitor thermistor temp. so this is the way that you can quickly make sure that your thermistors are working. (after you remove battery cables for 5 minutes to reset) It works!
Why does my international 4300 check a / C light?
Turns out it was the motor that switches the flaps in the dash from defrost to floor and vent now why that shuts the compressor down i have no idea but a $34.00 motor did the trick.
Why does my dt466e no start-fuel problem?
Got that all fixed. Realized that my primer pump would leak when I would pump it, replaced the entire assembly. Filled both filters, truck fired on the first try. Now today go to run a call, cranks and cranks wont start. Gave a shot of ether, fires but wont run on diesel.
Where is the fuel pump on a DT-466?
JaymZH2 wrote: fuel pump would be my guess. not sure on the older ones, but the newer DT’s it is on the drivers side mid block towards the front. a couple bolts a 2 lines and your done. I have a 2000 4700 DT-466, would what you call the fuel pump be the same thing they call the “high pressure pump” in the book that the lines from the filter go to??
What kind of fuel mileage does a dt466e get?
Btw: I have the 230 hp 660 tq engine and there seems to be plenty of power to run the 3.70 rear. I’ll have to hit the mfg. website and check how gradeability with the 3.70 compares to the 4.10, also I have to consider the cost, if the cost is higher than the possible fuel savings then I’ll just have to live with it.
Is the AC compressor on a Western Star working?
Discussion in ‘ Western Star Forum ‘ started by 04 LowMax, Jul 7, 2014 . Wondered if anyone has done any trouble shooting for this problem on a star? Was all prepared to head to a shop and get ac recharged, then thought I better just make sure the compressor is working. Good thing I did, it wasn’t. No 12 volts at comp plug.